Xiamen ZT Technology Co., Ltd.  Email: sales@zntar.com   zntarjason@gmai.com

CHB-05AD~25AD Closed-loop Hall Current Transducer

 CHB-05AD~25AD Closed-loop Hall Current Transducer

 

Closed-loop Hall current Transducer CHB-05AD~25AD

Input

0.5…25A

Output

As per your request

Φ

-

Email: sales@zntar.com

More details


Name/Model:   Closed-loop Hall Current Transducer CHB-05AD~25AD
  Rated input Parameter:   DC, AC or pulsed 0.5A~25A current

 

SENSOR MODULE  CHB-05AD~25AD

The SENSOR Module CHB-05AD~25AD is a closed loop Hall current sensor to measure 0.5A…25A DC, AC or pulsed currents with a galvanic isolation between the primary and secondary circuits.

 

 

Closed-loop Hall Current Sensor: 

Type

Nominal current

Output voltage

Accuracy

Supply voltage

Aperture

IN(A)

VM(V)

X(%)

Vc(V)

mm

CHB-05AD

0.5

5

±1.0%

±15

Terminals

CHB-1AD

1.0





CHB-2AD

2.0





CHB-5AD

5.0

5

±1.0%

±15

Terminals

CHB-8AD

8.0





CHB-10AD

10





CHB-15AD

15

5

±1.0%

±15

Terminals

CHB-20AD

20





CHB-25AD

25





 

Specifications:   

Principle

Closed loop Hall effect principle

Input current

0.5…25A(DC、AC、Pulsed current)

Output voltage

5V

Turns ratio

1~50:1000

Frequency

DC~100KHz

Accuracy

±1.0%

Response time

10μS

Linearity

<0.1%

Supply voltage

±15V(±5%)

Consumption

10mA+IM(Output current)

Isolation voltage

Between primary and secondary circuit: 2.5KV RMS/50Hz/1min.

Operating temp.

-25…+85℃

Mounting on

Fastening on panel

Applications

Power supplies, welding machines, converters, industry auto-control, motor drives,

For industry

electronic power system, railways, rectifiers systems etc.

Dimension(mm):